Whatever the requirements are, we provide either bare steam turbine drivers to OEMs, or we supply complete packages including gears, lube oil systems and controls. The Dresser-Rand steam turbines include standard single stage turbines for pump, fan & small compressor drives according to API 611 General Purpose (GP) standard, standard and engineered single stage turbines as generator drives for waste heat recovery applications and engineered single stage turbines and standard mulitstage turbines for applications according to API 611 (GP) or API 612 (Special Purpose – SP) standards. Its power output is 10kW up to 25 MW. The inlet steam pressure is 30 to 139 bar(a) and the inlet steam temperature is 415 to 550 °C.
We are a dedicated service provider for the legacy brands below including Dresser Rand, with regional service teams to support your local steam turbine maintenance needs. Our support includes OEM technical expertise for single stage, multistage and engineered multistage steam turbines. Our operations network features world-class factories, service centers, supplier network as well as warehouse logistics and inventory centers.
D-R RLH-15
D-R RLH-24
e.g. pumps or fans
Typical applications
D-R B
D-R Tandem
D-R B
D-R Tandem
Power output | Turbine speed | Inlet steam temperature | Inlet steam pressure | Back-pressure | Condensing pressure | Bleedings / Extractions | |
---|---|---|---|---|---|---|---|
D-R RLA | 240 kW | ≤ 4,300 to 6,000 rpm | ≤ 440 °C | ≤ 47 bar(a) | ≤ 12 bar(a) | ||
D-R RLVA | 240 kW | ≤ 4,300 to 6,000 rpm | ≤ 440 °C | ≤ 47 bar(a) | ≤ 12 bar(a) | ||
D-R RLH-15 | 1,865 kW | ≤ 6,000 rpm | ≤ 482 °C | ≤ 63 bar(a) | ≤ 21 bar(a) | ||
D-R RLH-24 | 1,865 kW | ≤ 6,000 rpm | ≤ 482 °C | ≤ 63 bar(a) | ≤ 21 bar(a) | ||
D-R SST 350/500/700 | 3,500 kW | ≤ 12,000 rpm | ≤ 482 °C | ≤ 63 bar(a) | ≤ 202 bar(g) | ||
D-R 2TA | 3,640 kW | ≤ 15,000 rpm | ≤ 530 °C | ≤ 101 bar(a) | ≤ 33 bar(a) | ||
D-R AVTTW | 4,500 kW | ≤ 13,000 or ≤ 5,000 rpm | ≤ 550 °C | ≤ 125 bar(a) | ≤ 40 bar(a) | ||
D-R GTW | 4,500 kW | ≤ 14,500 rpm | ≤ 550 °C | ≤ 125 bar(a) | ≤ 35 bar(a) | ||
D-R C | 2,500 kW | ≤ 8,500 rpm | ≤ 520 °C | ≤ 120 bar(a) | 21 bar(a) | ||
D-R GAF | 3,500 kW | ≤ 6,000 rpm | ≤ 440 °C | ≤ 49 bar(a) | ≤ 6 bar(a) | ≤ 0.05 bar(a) | |
D-R U | 6,340 kW | ≤ 10,000 rpm | ≤ 455 °C | ≤ 46 bar(a) | ≤ 15 bar(a) | ≤ 0.05 bar(a) | |
D-R R | 25,000 kW | ≤ 15,000 rpm | ≤ 482 °C | ≤ 63 bar(g) | ≤ 29 bar(g) | ≤ 0.05 bar(a) | 1 or multiple |
D-R RS | 25,000 kW | ≤ 15,000 rpm | ≤ 482 °C | ≤ 63 bar(g) | ≤ 29 bar(g) | ≤ 0.05 bar(a) | 1 or multiple |
D-R K | 4,850 kW | ≤ 10,000 rpm | ≤ 398 °C | ≤ 27.5 bar(a) | ≤ 5 bar(g) | ≤ 0.05 bar(a) | |
D-R B | 11,000 kW | ≤ 9,500 rpm | ≤ 500 °C | ≤ 65 bar(a) | 6,9 bar(a) | Multiple | |
D-R Tandem | 12,500 kW | ≤ 8,500 rpm | ≤ 530 °C | ≤ 111 bar(a) | ≤ 13 bar(a) | Multiple / 1 |
Power output | Turbine speed | Inlet steam temperature | Inlet steam pressure | Back-pressure | Condensing pressure | Bleedings / Extractions | |
---|---|---|---|---|---|---|---|
D-R RLA | 321 HP | ≤ 4,300 to 6,000 rpm | ≤ 824 °F | ≤ 682 psi | ≤ 174 psi | ||
D-R RLVA | 321 HP | ≤ 4,300 to 6,000 rpm | ≤ 824 °F | ≤ 682 psi | ≤ 174 psi | ||
D-R RLH-15 | 2501 HP | ≤ 6,000 rpm | ≤ 900 °F | ≤ 914 psi | ≤ 300 psi | ||
D-R RLH-24 | 2501 HP | ≤ 6,000 rpm | ≤ 900 °F | ≤ 914 psi | ≤ 300 psi | ||
D-R SST 350/500/700 | 4,690 HP | ≤ 12,000 rpm | ≤ 900 °F | ≤ 914 psi | ≤ 315 psi(g) | ||
D-R 2TA | 4,880 HP | ≤ 15,000 rpm | ≤ 986 °F | ≤ 1,515 psi | ≤ 480 psi | ||
D-R AVTTW | 6,000 HP | ≤ 13,000 or ≤ 5,000 rpm | ≤ 1022 °F | ≤ 1,813 psi | ≤ 508 psi | ||
D-R GTW | 6,000 HP | ≤ 14,500 rpm | ≤ 1022 °F | ≤ 1,813 psi | ≤ 508 psi | ||
D-R C | 3,250 HP | ≤ 8,500 rpm | ≤ 986 °F | ≤ 1,740 psi | 315 psi | ||
D-R GAF | 4,690 HP | ≤ 6,000 rpm | ≤ 825 °F | ≤ 715 psi | ≤ 87 psi | ≤ 0.7 psi | |
D-R U | 8,500 HP | ≤ 10,000 rpm | ≤ 815 °F | ≤ 664 psi | ≤ 214 psi | ≤ 0.7 psi | |
D-R R | 33,500 HP | ≤ 15,000 rpm | ≤ 900 °F | ≤ 915 psi | ≤ 421 psi | ≤ 0.72 psi | 1 or multiple |
D-R RS | 33,500 HP | ≤ 15,000 rpm | ≤ 900 °F | ≤ 915 psi | ≤ 421 psi | ≤ 0.72 psi | 1 or multiple |
D-R K | 6,500 HP | ≤ 10,000 rpm | ≤ 750 °F | ≤ 415 psi(a) | ≤ 75 psi(g) | ≤ 0.7 psi | |
D-R B | 14750 HP | ≤ 9,500 rpm | ≤ 932 °F | ≤ 942 psi | 304 psi | Multiple | |
D-R Tandem | 16765 HP | ≤ 8,500 rpm | ≤ 986 °F | ≤ 1,610 psi | ≤ 188 psi | Multiple / 1 |
Turbodyne
Models: Model R, Model U, Model S, Model T, R 2 R, U 2 U, S 2 R, T 2 R, 120, 140, 160, 200, 280, 280LP, 123M, 123W, 123T, 123WHB, 120, 140, 160, 200, 280, 300, 350, 500, 700, 700LP, 353M, 353T, 353W
Terry
Models: Z-1-J, Z-1, Z-4, ZS-1, ZS-4, ZAT, 18Z, 18ZS, 24Z, 24ZS, E, ES, ESA, G, GANB, SA-520, SA-730, ZV, EV, GLT-260, GLT-360, Z, ZS, GANB, C, CS, CSS
Moore
Models: R, U, S, T, R2R, U2R, S2R, T2R
Worthington
Models: 123, 143, 163, 203, 283, RN, RNV, SN, SNV, R, U, S, T, R2R, U2R, S2R, T2R
COPPUS
Models: TF – 12,16,20,22,23; RL – 12,16,20,22,23; RLA – 12,16,20,22,23; RLH – 19, 24,28; RLHA – 19,24; RLHB – 19, 24; RLV – 12,16,,20,22,23; RLVA – 12,16,20,22,23
Carling
Models: A12, A16, A20, C24, A 9A, 12A,16A,20A,24A, AV 9AV,12AV, 16AV,20AV,24AV, C 12C,16C,20C,24C
McGraw-Edison
Models: 120, 140, 160, 200, 280, 300, 350, 500, 700, 700LP, 353M, 353T, 353W
Nadrowski
Models: SERIES C, MODEL C375, MODEL C4, MODEL C5, MODEL C7, SERIES B, MODEL B5, MODEL B7
Murray
Models: MODEL R, MODEL U, MODEL K
In our download section, you can find brochures, technical papers, and more.