Industrial steam turbines – tailor-made and flexible

Efficiency turns less into more.


As a market leader for industrial steam turbines, we offer a comprehensive range of reliable and versatile steam turbines for the power output range from 2 to 250 MW. Our industrial steam turbines are designed for easy constructability, fast start-up and economical operation. The inlet steam pressure is 103 to 160 bar(a) and the inlet steam temperature is 400 to 565 °C
 

Do you have a question regarding our products, solutions and services?

  • Power output up to 200 MW  
  • Speed 3,000 to 7,100 rpm
  • Inlet pressure up to 165 bar / up to 2,393 psi
  • Inlet temperature up to 565 °C / up to 1,050 ° F
  • Exhaust steam parameters: up to 80 bar / 1,160 psi
  • Controlled extractions (up to 2)Pressure ext. valve up to 65 bar / 942 psi
  • Uncontrolled extractions: (up to 6): Various pressure levels
  • Combined cycle power plants (CCPP)
  • Combined heat and power plants (CHP)
  • Concentrated solar power plants (CSP)
  • Biomass plants and waste-to-energy plants (WtE)
  • Industrial power plants, e.g. captive power plants in chemical and petrochemical industries, manufacturing industries, paper mills, mines, metal, and cement plants, waste heat recovery
  • Oil & gas industries
  • DIstrict heating plants
  • Power output up to 250 MW (CCPP: 230 MW)   
  • Speed 3,000 to 3,600 rpm
  • Inlet pressure up to 180 bar / up to 2,611 psi 
  • Inlet temperature up to 585 °C / up to 1,085 ° F
  • Exhaust steam parameters: up to 0.3 bar / 4.4 psi
  • Reheat steam temperature: 565°C / 1,050°F
  • Reheat steam pressure: 45 bar(a) / 842 psi
  • Controlled extractions: 72 bar / 1,044 psi
  • Uncontrolled extractions (up to 7): uncontrolled extractions 
  • Combined cycle power plants
  • Concentrated solar-thermal power plants
  • Biomass-fired power plants
  • Power output up to 200 MW   
  • Speed 3,000 to 18,000 rpm
  • Inlet pressure up to 165 bar / up to 2,393 psi
  • Inlet temperature up to 565 °C / up to 1,050 ° F
  • Exhaust steam parameters:
    Back pressure
     up to 80 bar / 1,160 psi 
    Condensing up to 1.0 bar / 15 psi
    District heating up to 3.0 bar / 43 psi
  • Controlled extractions:
  • Pressure, ext. valve up to 72 bar / 1,044 psi
    Pressure, int. valve up to 45 bar / 798 psi
    Temperature up to 480 °C / 895° F
  • Uncontrolled extractions (up to 6): up to 85 bar / 1,233 psi
  • Chemical and petrochemical industry
  • Pulp and paper mills
  • Steel works
  • Mines
  • Power plants
  • Seawater desalination plants
  • Biomass and Waste-to-energy
  • Power output up to 100 MW   
  • Speed up to 15,000 rpm
  • Inlet pressure up to 30 bar / up to 435 psi 
  • Inlet temperature up to 400 °C / up to 750 ° F
  • Exhaust steam parameters:
    District heating up to 1.5 bar / 21.75 psi
    Condensing up to 0.5 bar / 7.25 psi
  • Steam extraction: Uncontrolled (up to 2), various pressure levels
  • Pump drive, e.g. feedwater pump for large boilers
  • Generator drive
  • Compressor drive
  • Chemical industry
  • Steel works
  • Waste to energy, e.g. waste incinerators
  • Waste heat recovery
  • Power output up to 60 MW   
  • Speed 8,000 rpm
  • Inlet pressure up to 140 bar / up to 2,030 psi 
  • Inlet temperature up to 540 °C / up to 1,004 ° F
  • Exhaust steam parameters: 
    Back pressure 
    up to 25 bar / 363 psi
    Condensing 
    up to 0.3 bar / 4.4 psi
  • Steam extraction
    Controlled (up to 4) 
    up to 45 bar / 510 psi
    Uncontrolled 
    up to 60 bar / 870 psi
  • Combined cycle power plants (CCPP)
  • Biomass plants and waste-to-energy (WtE)
  • Industrial power plants
  • Waste heat recovery
  • District heating
  • Mechanical drive
  • Power output up to 45 MW  
  • Speed 12,000 rpm
  • Inlet pressure 140 bar / up to 2,030 psi
  • Inlet temperature 540 °C / up to 1,004 ° F
  • Exhaust steam parameters: 
    Back pressure 
    up to 16 bar / 232 psi
    Condensing 
    up to 0.3 bar / 4.4 psi 
    District heating
     up to 3.0 bar / 43 psi
  • Controlled extractions (up to 2): Single or double, adaptive stage, nozzle control, throttle control 
    Pressure 
    up to 25 bar / 362 psi
    Temperature 
    400 °C / 752° F
  • Uncontrolled extractions (up to 6): up to 60 bar / 870 psi
  • Combined cycle power plants (CCPP)
  • Combined heat and power plants (CHP)
  • Concentrated solar power plants (CSP)
  • Waste-to-energy plants (WtE), e.g. waste incineration
  • Biomass plants
  • District heating plants
  • Chemical and petrochemical industry
  • Pulp and paper mills
  • Sugar industry
  • Steel works
  • Mining industry
  • Cement industry
  • Power output: up to 20 MW
  • Inlet steam pressure: up to 120 bar (a) / 1,740 psi
  • Inlet steam temperature: up to 540º C / 1,004° F
  • Exhaust conditions:
    Water-cooled condenser: 0.05–0.15 bar (a)
    Air-cooled condenser: 0.15–0.50 bar (a)
    Backpressure turbines: 2–20 bar (a) 
    Uncontrolled extraction: 60 bar / 870 psi (up to 3)
    Controlled extraction: 16 bar / 230 psi
  • Sugar industry
  • Chemical and petrochemical industry
  • Biomass plants
  • Mechanical drive
  • Metals and mining
  • Energy from waste

Everything at a glance

 Power outputTurbine speedInlet steam pressureInlet steam temperatureBack-pressureCondensingControlled extractionsUncontrolled extractions
SST-800up to 200 MW3,000 to 7,100 rpmup to 165 barup to 565 °Cup to 80 barup to 1.1 barup to 2up to 6
SST-800/500up to 250 MW3,000 to 7,100 rpmup to 120 barup to 585 °Cup to 80 barup to 1.1 barup to 2up to 6
SST-700/900up to 250 MW (CCPP: 230 MW)3,000 to 3,600 rpmup to 180 barup to 585 °C0.3 bar  up to 7
SST-600up to 200 MW3,000 to 18,000 rpmup to 165 barup to 565 °Cup to 80 barup to 1.0 bar
up to 2
up to 6 (up to 85 bar)
SST-500up to 100 MWup to 15,000 rpmup to 30 barup to 400 °C up to 0.5 bar up to 2 (various pressure levels)
SST-400up to 60 MWup to 8,000 rpm
up to 140 barup to 540 °Cup to 25 barup to 0.3 barup to 4up to 60 bar
SST-300up to 45 MWup to 12,000 rpm140 bar540 °Cup to 16 barup to 0.3 barup to 2*up to 6 (up to 60 bar)
SST-200up to 20 MWup to 12,000 rpmup to 120 barup to 540 °Cup to 16 barup to 0.25 bar16 bar60 bar
*single or double, adaptive stage, nozzle control, throttle control
 Power outputTurbine speedInlet steam pressureInlet steam temperatureBack-pressureCondensingControlled extractionsUncontrolled extractions
SST-800up to 200 MW3,000 to 7,100 rpmup to 2,393 psiup to 1,050 °Fup to 1,160 psiup to 16 psiup to 2up to 6
SST-800/500up to 250 MW3,000 to 7,100 rpmup to 1,740 psiup to 1,085 °Fup to 1,160 psiup to 16 psiup to 2up to 6
SST-700/900up to 250 MW (CCPP: 230 MW)3,000 to 3,600 rpmup to 2,611 psiup to 1,085 °F4.4 psi  up to 7
SST-600up to 200 MW3,000 to 18,000 rpmup to 2,393 psiup to 1,050 °Fup to 1,160 psiup to 15 psi
up to 2
up to 6 (up to 1,233 psi)
SST-500up to 100 MWup to 15,000 rpmup to 435 psiup to 750 °F up to 7.25 psi up to 2 (various pressure levels)
SST-400up to 60 MWup to 8,000 rpm
up to 2,030 psiup to 1,004 °Fup to 363 psiup to 4.4 psiup to 4up to 870 psi
SST-300up to 45 MWup to 12,000 rpm2,030 psi1,004 °Fup to 232 psiup to 4.4 psiup to 2*up to 6 (up to 870 psi)
SST-200up to 20 MWup to 12,000 rpmup to 1,740 psiup to 1,004 °Fup to 230 psiup to 3.6 psi230 psi870 psi
*single or double, adaptive stage, nozzle control, throttle control

Find out more about our products and services


In our download section, you can find brochures, technical papers, and more.

Product information
PDF (7 MB)

References

More than 20,000 steam turbines were delivered to sites all over the world within the past 100 years. Find below some chosen examples

Berlin, Germany (2018)

  • Customer: Vattenfall, Heat and power station Berlin-Marzahn
  • Scope: SGT-5-2000E gas turbine, SST-800 steam turbine, Sgen-100A generator, auxiliary equipment
  • Starting in 2020, the new plant in Berlin-Marzahn will supply district heating and electricity for around 150,000 residential units with more than 90 % fuel efficiency: power output is 230 MWth and 270 Mwe

Chaiyaphum, Thailand (2015)

  • Customer: Mitr Phol Bio Power Co., Ltd
  • Power output: 45 MW
  • Scope: 2 x SST-300 steam turbines, PCS7 I&C system, 2 x SST-300 turbogenerator set

Lincoln, United Kingdom (2011)

  • Customer: CNIM / FCC Environment
  • Power output: 15.25 MW (e), 10 MW (th)
  • Burns 150,000 tonnes of municipal waste per year, operating 24 hours per day
  • Scope: SST-300 steam turbine